133 HE Plus - absolute nightmare Written on: 17/01/2013 We had a 133 HE Plus fitted just over 4 years ago by a Corgi Registered Plumber (ex British Gas employee) We have had nothing but trouble with it It was 4 weeks out of Guarantee when we were getting loud banging noises when it fired
Learn MoreReposition the thermostat so there are none of these kinds of items between the and the thermostat 4 Turn the heating It sounds silly but maybe the heating isnt coming on because its just not cold enough! Your heating will only when the
Learn More· Can someone give me a bit of advice regarding my Worcester Bosch 24i The hot tap at the sink and wash basin is very very hot but when taking a shower the cuts in and out It will and run for about a minute and then cut off for a few and then back If I leave a hot water tap running slowly it stays on
Learn MoreThe doesn't have power: The circuit breaker or fuse controlling the furnace may have tripped or blownReset the tripped circuit breaker or replace a blown fuse; The water level is low: Maintain the water level in the at half-fullThe automatic filling system controlled by the pressure-reducing valve should maintain the proper water level at 12 to 15 psi of pressure
Learn MoreMost modern run smoothly without ever causing you much grief and maintenance and in particular have a growing reputation for quality and value There are rare instances though where problems will arise and the below should give you a quick idea of what to expect if your is giving you a rare problem
Learn More· My is playing I switched the hot water and heating off over the weekend as I was away and left the alone Having turned the timers back on the will but only for a short time The green ON light then cuts off!!
Learn More· I have a Worcester oil fired about years old that has been working ok but recently I have noticed that it fires very frequently as often as once 5 minutes all day It did not do this before The thermostat on both the hot water and the central heating seem to work ok
Learn MoreWith a demand present for the to this Solo 2 PF 50 couldn't complete the ignition cycle The fan would start and stop repeatedly on a very short cycle of under one This is a fault we've seen before on Solo PF and is caused by damage to the
Learn MoreWith a demand present for the to this Solo 2 PF 50 couldn't complete the ignition cycle The fan would start and stop repeatedly on a very short cycle of under one This is a fault we've seen before on Solo PF and is caused by damage to the
Learn MoreThis could be a problem with your it could be your system is gunked or it could be your thermostat commanding the heating system to turn on and off My money would be the and not the thermostat but you could take the communication wires out of the thermostat and twist them together for awhile to see if your stays on
Learn More· If your then turns off then this is likely to be preheat function This is nothing to worry about and simply ensures theres some hot water ready to be sent to taps when you need it However if it then quickly turns off again this could be sign
Learn More133 HE Plus - absolute nightmare Written on: 17/01/2013 We had a 133 HE Plus fitted just over 4 years ago by a Corgi Registered Plumber (ex British Gas employee) We have had nothing but trouble with it It was 4 weeks out of Guarantee when we were getting loud banging noises when it fired
Learn MoreIf your timer is calling for heat the burner light will come on to indicate the boiler has and is heating your system If lockout occurs frequently fault is indicated and you should contact your installer or service engineer If you are troubleshooting that uses
Learn MoreFixing combie that when the cold tap is used after wed had a few plumbing jobs done we noticed that our Combie was turning itself on time we used a cold tap Or more precisely the turned itself on briefly a few after we turned a cold tap off This seemed very odd because the whole point of
Learn More· One major flaw in this plan is that a itself back morning tends to use a higher amount of energy than just leaving it on overnight If one of the main concerns regards cost is how much your uses when not actually in use at the taps or for the central heating then it may be time to consider a new
Learn MoreI have a + it when the heating + water are off It fires stays on for a few mins goes off for a few mins + then does it again It has been doing it constantly day + night for the past couple of days but it doesn't do it few minutes likes yours suzetommo 01:15 Wed 16th Nov 2011 buildersmate
Learn MoreIf your is turning on but going off the pressure could be low or there could be a blockage that is inhibiting the system Check your systems pressure gauge and repressurise the if it is set below 1 Alternatively contact a Gas Safe registered engineer Book a repair Get a quote for a new breakdown
Learn More· top the to 2 barthen close the two valves beneath the on the flow and return pipesdon't use the for a couple of hours then go back and look at the gauge it should still be at 2 barthen open the two valves again if the pressure drops it's a leak on the system and not on the
Learn Morethe in our new house the timer is turned off but hour or so it turns itself on for a few minutes which is I wonder if it is a with a quick start facility that itself hot to reduce delay when you turn on a tap Mine comes on for 60 at exactly 23:23
Learn MoreDoes dropping? Your losing is an occurrence more natural than childbirth and overtime (or sometimes overnight) theyre bound to lose some water () and require topping (or repressurised) So if this is your first rodeo relax However if your dropping it may be a sign of a more serious problem?
Learn More· Older are more prone to faults and over the years Ive received quite a few calls about old faulty Worcester Its no fun having a faulty especially if you dont know how extensive the work is or how much itll cost to fix So below Im going to go over some of the most common Worcester faults and fixes
Learn More· Your is so the fan and air pressure switch are operating correctly When the fires the flame sensor has to detect a flame This then sends an electrical signal to the pcb If this signal is not reaching the pcb your will switch
Learn More· Common fault 1: Solo 1PF and 2PF lockout If your has gone into lockout its most likely due to the overheating and this should be a relatively easy fix you can try on your own The Fix: First check your s pressure and top if necessary
Learn More· Hi all thanks for your advice re-my cutting out shortly after I tried bleeding the pump and two bleed points that were either side of the pump no difference I removed the cover from the pump power cables and there was no power present Flicked the power isolation off held the tester on the pump cables switched the power back on and the lights lit on the tester for a
Learn MoreAlso asked how do I reset my ? To reset the turn the selector switch to the R (Reset) positionHold for at least 5 and release The fault code will be replaced with the current temperature At this point on a neon indicator model the flame failure light will stop flashing and will be replaced with the burner light
Learn MoreDelayed ignition is a problem thats common in gas that use pilot lights (as opposed to electronic ignition systems) You see during normal operation when a gas receives the call for heat the gas valve opens and releases a small amount of gas into a sealed combustion chamber via small jets
Learn MoreA blocked air filter is now one of the most common causes of problems The air filter in a is not unlike the filters you will find in a vacuum cleaner or car If the air filter is user-serviceable remove it and clear it of any dirt build with a vacuum cleaner or dry brush
Learn MoreThis could be a problem with your it could be your system is gunked or it could be your thermostat commanding the heating system to turn on and off My money would be the and not the thermostat but you could take the communication wires out of the thermostat and twist them together for awhile to see if your stays on
Learn Morelockout is common reason for boiler failing to ignite which happens when theres fault with the boiler that could lead to damage if the boiler was to continue operating Common causes of locking out include overheating (110) fan fault (160) flue overheating (E131) and an issue with the printed circuit board (PCB) (E168)
Learn More· When my starts from cold it runs continuously for about 30mins to get to temperature shuts down for about 5mins and then flares again for around mins and so on The timing will depend a lot on how many radiators you have the room temperature (ie how fast the radiators radiate) and the setting of the thermostat which
Learn More· Your is so the fan and air pressure switch are operating correctly When the fires the flame sensor has to detect a flame This then sends an electrical signal to the pcb If this signal is not reaching the pcb your will switch
Learn Morethat are 8- years old are certainly not as advanced as new We already know there is a diverter valve fault Get the engineer to check the rest of the parts thoroughly If there is anything else majorly wrong with the its worth considering a new Find out the cost of a new
Learn MoreIf your is turning on but going off the pressure could be low or there could be a blockage that is inhibiting the system Check your systems pressure gauge and repressurise the if it is set below 1 Alternatively contact a Gas Safe registered engineer Book a repair Get a quote for a new breakdown
Learn MoreA lockout is a common reason for the failing to ignite which happens when theres a fault with the that could lead to damage if the was to continue operating Common causes of a locking out include overheating (110) fan fault (160) flue overheating (E131) and an issue with the printed circuit
Learn More· I have recently installed and commisioned a 30kw main eco It passed all the relevant checks and is running perfectly but the customer said that while he was asleep he could hear the for a number of then go back into standby mode I had noticed it
Learn More· However the is still intermittently more than an hour and a half later and the pilot light flashing green and after a while it would turn amber (as if to switch off) but then it flashes green again It fires only for a little while and it doesn't stay fired for long
Learn More· hi all i have a main 30hethe promlem with the is that when there is a demand for constant heating the fires and the temp' 30deg' neon light comes on then within a couple of minutes of the running the temp' rises to max 80 deg' only three radiators get hot and then the shuts down after about minutes the fires and the process starts all
Learn MoreE168 Error Code When your has issue but cannot work out where problem is it will show this error most common cause for seeing this code is when there is problem with electrical supply (PCB lockout error)
Learn More· HelloMy 4 minutes interval when there is no HW and CH demand Please bear with me with the long description belowI moved into my current house in this summer At that moment the HW of the (Worcester 24i RSF ) was working intermittently
Learn MoreFault Finding Charts and Tables The troubleshooting manuals below is an easy step by step process to fault find your For a quick and easy check conduct the following: Electrical Analyse the electrical circuits by using a multimetre inspecting for for short circuits earth continuity and earth resistance Check that the system has correct polarity 230V Supply
Learn More